October 1, 2014

Particle Quantifier Index (PQ) – A Complementary Test

The particle quantifier index test measures the mass of ferrous wear debris in a sample and displays this as PQ index by Hall Effect regardless the particle size. The Hall Effect is a measurable induced voltage across a sample. The higher the observed Hall voltage, the higher the concentration of ferromagnetic wear debris present.
April 10, 2014

Synthetic Lubricants

We often get questions on the difference between the various types of lubricating oils: mineral based, synthetic-based and bio-based oil. We will deal with mineral and bio based oils in subsequent issues. A symplistic explanation is that mineral oils are refined petroleum products whereas bio-based oils (most being vegetable oils), are extracted from various crops such as soya, corn, canola, etc. A fourth type of oil, namely re-refined oil is also considered as base oil. However, in this article will be focusing solely on synthetic oil.